TWIN TMA AWS, LOWPASS
Designed to be used at co-located 700MHz and AWS sites, the Kaelus TMA2043 provides internal diplexing of the two bands. External diplexers and feeders are no longer required, resulting in decreased hardware costs, environmental impact and tower licensing fees.
주요특징
- LTE ready
- AISG 2.0 compatible, fully software upgradable
- Provides gain in the AWS path and bypass to 700MHz frequencies
- Excellent noise figure performance
- Full lightning protection and fail safe bypass mode
기술 사양
DOWNLINK AWS (TX) PATH
Passband |
2110 - 2170MHz |
Insertion loss |
0.25dB typical |
Return loss |
18dB minimum |
Maximum input power |
500W (average) / 5kW (PEP) |
UPLINK AWS (RX) PATH
Passband |
1710 - 1770MHz |
Nominal gain |
12dB minimum |
Noise figure |
1.1dB typical |
Return loss |
18dB minimum operating, 15dB minimum in bypass mode |
Bypass loss |
2dB typical |
Output IP3 |
+26dBm typical |
Rejection in TX band |
80dB minimum |
Rejection @ 1700MHz |
25dB minimum |
Rejection @ 1800MHz |
25dB minimum |
700 MHZ BYPASS
Passband |
698 - 746MHz |
Insertion loss |
0.25dB typical |
Return loss |
18dB minimum |
Maximum input power |
500W (average) / 5kW (PEP) |
ELECTRICAL
Intermodulation products |
-155dBc maximum at antenna ports with 2 x 20W carriers |
GENERAL SPECIFICATIONS (MEASURED IN 180KHZ BANDWIDTH)
Phase linearity, 700 & AWS |
0.02° typical |
Group delay variation, 700 & AWS |
0.8ns typical |
Amplitude variation, 700 & AWS |
0.02dB typical |
POWER SUPPLY AND ALARM (CURRENT WINDOW ALARM MODE, DEFAULT)
CWA is the default TMA operating mode and can be configured to specific customer requirements. The TMA is configured so that each BTS port is individually powered and monitored. Each BTS port sinks additional current to indicate an alarm state in its uplink path. Normal operating and alarm current values are configured independently and are alterable via a field-loadable personality file, contact Kaelus for more information. |
DC supply voltage |
7.5V to 30V DC, case is DC ground |
DC supply |
Through BTS connector |
DC supply current, normal mode |
100 ± 20mA per port |
DC supply current, alarm mode |
200 ± 30mA per port |
POWER CONSUMPTION
Normal operation |
0.85W @ 7.5V, 3W @ 30V typical |
Alarm mode |
3W @ 15V per port typical |
AISG MODE OF OPERATION (AUTO SELECTED ON VALID AISG 2.0 FRAMES)
AISG signals can be applied to either BTS0 or BTS1 port. The TMA unit switches to AISG mode when valid frames are detected on one of the BTS ports. The TMA unit is DC powered (common feed for both channels) from the port supplying the AISG frames. |
DC supply voltage |
7.5V to 30V DC, case is DC ground |
AISG version |
2.0 (1.1 optional) |
Supply current, AISG mode |
200mA @ 7.5V, 65mA @ 30V typical |
Voltage drop, BTS to AISG port |
1.5V maximum at 2A |
Power consumption, AISG mode |
1.5W @ 7.5V, 2W @ 30V typical |
AISG connector, current rating |
IEC60130-9, 8-pin female / < 4A peak, 2A continuous, pin 6 |
ENVIRONMENTAL
For further details of environmental compliance, please contact Kaelus. |
Temperature range |
-40º to +65ºC | -40º to +149ºF |
Ingress protection |
IP67 |
Lightning protection |
IEC61312-1, RF: ±5kA maximum (8/20us), AISG: ±2kA maximum (8/20us) |
MTBF |
>700,000 (hours) |
Compliance |
FCC Part 15, Ingress ETSI EN 300 019 class 4.1, RoHS |
MECHANICAL
Dimensions H x D x W |
284 x 181.5 x 89mm | 11.18 x 7.14 x 3.5in (excluding brackets and connectors) |
Weight |
9kg | 20lbs |
Finish |
Painted, light grey (RAL7035) |
Connectors |
DIN 7-16 (F) x 6 long neck |
Mounting |
Pole/wall bracket supplied with two metal clamps 45-178mm diameter poles |
주문 정보
Part Number |
Description |
TMA2043F1V1-1 |
Twin TMA, 700MHz bypass, with pole mounting bracket |
ELECTRICAL BLOCK DIAGRAM